Get more info . . .
Technical Data

Brochures
On-Line Catalog
Specifications
(CSI Standards)

Competitive Cross Reference

PowerPact Circuit Breakers

PowerPact® M-, P- and R-Frame Molded Case Circuit Breakers

PowerPact molded case circuit breakers are offered in unit-mount construction and I-Line® plug-on construction, with a variety of terminations. These PowerPact circuit breakers are available with electronic trip units.

Molded Case
Frame Model
Tripping System
Max. Ampere Rating
Electronic Trip
800 A
Electronic Trip
1200 A
Electronic Trip
3000 A

PowerPact M-Frame Molded Case Circuit Breakers

PowerPact M-Frame Molded Case Circuit Breakers provide improved
performance and a compact solution for up to 800A applications. Powerpact M-Frame Molded Case Circuit Breakers are available in unit mount and I-Line versions with two levels of interrupting rating (AIR): G rating (65/35/18 kA) and J rating (100/65/25 kA) at 240/480/600 Vac. The electronic trip unit type ET 1.0 has a fixed long-time pick-up and delay with adjustable instantaneous pick-up.

  • Connection options include bus, standard lug, crimp lug and distribution lug are available for installation flexibility
  • Various padlocking and key-lock options are available to comply with OSHA requirements
  • Dual rated UL489 and IEC 60947-2
  • Available 300A, 350A, 400A, 450A, 500A, 600A, 700A and 800A ratings
  • Available in 2- and 3-pole unit-mount and I-Line versions

<Top>

PowerPact P and R-Frame Molded Case Circuit Breakers

PowerPact P- and R-Frame molded case circuit breakers provide high-end sophistication, flexible connection capabilities, high interrupting ratings and field-installable accessories in a small package. The P-frame circuit breaker is available in standard and 100% ratings with sensor sizes of 250-1200 A with interrupting ratings (AIR) of G-35kAIR, J-65kAIR and L-100kAIR at 480Vac. The R-frame circuit breaker is available in standard and 100% ratings with sensor sizes 600-3000 A with interrupting ratings of (AIR) G-35kAIR, J-65kAIR and L-100kAIR at 480Vac.

  • UL 489/IEC 60947-2 dual rated
  • Meet federal specification W-C-375B(GEN)
  • Available with Micrologic® Trip Units with PowerLogic® power metering and monitoring capabilities available with advanced trip units
  • Compatible with PowerLogic systems and high amperage power circuit breakers
  • Built-in Modbus® protocol for open communication platform
  • Available for I-Line® panelboards and switchboards

<Top>

   
   